SCBA Electric Pressure Gauge

SCBA Electric Pressure Gauge

The SCBA positive pressure gauge air respirator electronic sound and light alarm is a new generation of residual air pressure alarm equipment designed and manufactured in accordance with the requirements of MCS.339(91). It is specially used for residual pressure alarm of air respirators.
Send Inquiry
Description
Technical Parameters

The SCBA positive pressure gauge air respirator electronic sound and light alarm is a new generation of residual air pressure alarm equipment designed and manufactured in accordance with the requirements of MCS.339(91). It is specially used for residual pressure alarm of air respirators. It combines a pointer pressure gauge with an electronic sound and light alarm. When the pressure in the cylinder drops to 5.5±0.5MPa, the alarm emits a continuous buzzing sound and red and white strong light flashing signals. Compared with the traditional pneumatic whistle alarm, the electronic sound and light alarm has the function of simultaneous alarm sound and light, and the function of light prompts at different pressure levels to ensure that respirator users or on-site monitoring personnel receive residual information through a variety of prompt methods. Air pressure information and alarm signals can effectively ensure the breathing and safe evacuation of users.

 

Integrated design of digital pressure gauge and mechanical pointer pressure gauge

 

The waterproof structure design prevents rainwater and moisture from entering the inside of the pressure gauge during operation.

Fluorescent design allows operators to clearly observe values in dark environments

Red alarm area, clear and easy to see

Excellent seismic performance, able to cope with various harsh operating environments

Wide range design to meet various design working pressure requirements

Explosion-proof design increases safety

This product has compact structure, small size, easy operation and good explosion-proof performance.

 

This product is powered by 1 piece of 3.0V lithium batteries, model CR123A

 

Radio frequency source power<4mW.

ingress protection level: IP67.

Service temperature: -35°C to +60°C

 

Instructions

 

1. Start up

Press the power switch key and the indicator light will light up, and the electronic sound and light alarm will enter working status.

The electronic alarm has an automatic start-up function. When the air pressure in the gas cylinder is greater than 2MPa, open the gas cylinder valve switch, and the electronic alarm will automatically turn on and enter the working state.

2. Shut down

To shut down, you need to press and hold the power button for 3 seconds to prevent unintentional shutdown.

Before shutting down, the remaining air in the high-pressure pipe must be completely depressurized. If the air pressure in the system is greater than 2MPa, the alarm will automatically be in working mode and cannot be turned off.

3. Alarm status

When the air pressure in the cylinder drops to 5.5±0.5MPa, the electronic alarm buzzer emits a continuous chirping sound greater than 90dB. At the same time, the four LED lights around the pressure gauge emit white flashes and the power indicator light emits red flashes.

4. Other display states

a Air pressure indicator light

When the air pressure in the cylinder is greater than 10MPa, the air pressure indicator light is always green;

When the air pressure in the cylinder is greater than 6MPa and less than 10MPa, the air pressure indicator light is solid yellow;

When the air pressure in the cylinder is less than 6MPa, the air pressure indicator light will flash in red.

b Battery indicator light

When the battery power is only 20% of the total power, the power undervoltage indicator light (yellow light) starts to light up.

 

Precautions

 

1. The electronic sound and light alarm uses CR123 lithium battery, and batteries of other specifications must not be used instead.

2. When replacing the battery, the alarm should be turned off first. It is strictly forbidden to replace the battery while the power is on. Replaced used batteries should be stored in a centralized manner according to battery recycling rules and should not be thrown around to pollute the environment.

3. After replacing the battery, make sure the battery compartment is completely sealed.

 

HUD Pressure Head-Up Display

 

Wirelessly connect to personal monitoring unit to observe cylinder pressure in real time

Reduce the frequency of checking the pressure gauge and observe the cylinder pressure in real time

Suitable for various types of masks, more convenient to install and use

Low pressure alarm to ensure users' life safety

Low power consumption, automatic alarm when battery is low

Teammate light reminder, more safety and security

Evacuation alarm prompt (requires Hoton Security TM system network support)

 

Medium voltage system

 

When the pressure in the cylinder is as low as 5.5±0.5MPa, the alarm whistle will sound, and the whistle will sound continuously. The sound level measured within 1 meter exceeds 90dB. The alarm whistle lasts for more than 8 minutes, and the gas consumption is Only 3L/min.

 

Hot Tags: scba electric pressure gauge, China scba electric pressure gauge manufacturers, suppliers, factory, Inflatable Foot Pump, Kayak Fishing Life Jacket, Survival Suit, Copper Pulley, Parallel Ruler, Inflatable Life Jacket